MCX F RA Solder PCB Mount SMT
| Frequency Range |
DC-6 GHz |
|---|---|
| Impedance |
50Ω |
| Voltage Rating |
250 V peak |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: 3Ω; Outer Contact: 2Ω |
| VSWR |
≤1.3 |
| Durability (matings) |
503 (Slide-on ,push-pull ,threaded) |
| Body and Outer Contacts |
berylium & gold plated ,Brass |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-25 to +100 |
MCX M RA CRIMP for BT-3002 Cable
| Frequency Range |
DC-6 GHz |
|---|---|
| Impedance |
50Ω |
| Voltage Rating |
250 V peak |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: 3Ω; Outer Contact: 2Ω |
| VSWR |
≤1.3 |
| Durability (matings) |
504 (Slide-on ,push-pull ,threaded) |
| Body and Outer Contacts |
berylium & gold plated ,Brass |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-25 to +100 |
MMCX F RA PCB Mount Without Stand-off
| Weight | 0.015 kg |
|---|---|
| Frequency Range |
DC-3 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
265 V rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤1 mΩ; Outer Contact: ≤0.5 mΩ |
| VSWR |
≤1.2 |
| Durability (matings) |
≥ 500 |
| Body and Outer Contacts |
Brass ,gold plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-40 to +90 |
MMCX M RA CRIMP for LMR100/RG174/RG316 Cable
| Weight | 0.015 kg |
|---|---|
| Frequency Range |
DC-3 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
265 V rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤1 mΩ; Outer Contact: ≤0.5 mΩ |
| VSWR |
≤1.2 |
| Durability (matings) |
≥ 500 |
| Body and Outer Contacts |
Brass ,gold plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-40 to +90 |
MMCX M RA CRIMP for RG178 Cable
| Weight | 0.015 kg |
|---|---|
| Frequency Range |
DC-3 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
265 V rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤1 mΩ; Outer Contact: ≤0.5 mΩ |
| VSWR |
≤1.2 |
| Durability (matings) |
≥ 500 |
| Body and Outer Contacts |
Brass ,gold plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-40 to +90 |
MMCX M RA Solder for Semi-rigid .086/RG405 Cable
| Weight | 0.015 kg |
|---|---|
| Frequency Range |
DC-3 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
265 V rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤1 mΩ; Outer Contact: ≤0.5 mΩ |
| VSWR |
≤1.2 |
| Durability (matings) |
≥ 500 |
| Body and Outer Contacts |
Brass ,gold plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-40 to +90 |
N F BH RA Solder for RG58/RG142/LMR195/LMR 200 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N F RA CLAMP for LMR240 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for 1/2″ Feeder Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for 1/2″ Super Flexible Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for 1/4″ Feeder Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for 1/4″ Super Flexible Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for LMR240 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for LMR300 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for LMR400/RG8/RG11/RG213/RG393 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for LMR600 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CLAMP for RG58/RG142/LMR195/LMR200 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CRIMP for LMR100/RG174/RG316 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CRIMP for LMR240 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CRIMP for LMR300 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CRIMP for LMR400/RG8/RG11/RG213/RG393 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA CRIMP for RG58/RG142/LMR195/LMR200 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA Solder for 1/2″ Feeder Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |
N M RA Solder for Semi-rigid .141/RG402 Cable
| Weight | 0.03 kg |
|---|---|
| Frequency Range |
DC-6 GHz |
| Impedance |
50Ω |
| Dielectric withsanding V |
2.5 kV rms |
| Insulation resistance |
≥ 5000 MΩ |
| Contact resistance |
Inner Contact: ≤2 mΩ; Outer Contact: ≤1.5 mΩ |
| RF leakage |
-90 dB minimum at 3 GHz |
| Durability (matings) |
5/8-24 threaded coupling |
| Body and Outer Contacts |
Brass ,gold & silver plated |
| Compliance |
ROHS |
| Operating Temperature(℃) |
-50 to +120 |